“T”type K100 capsule filter:It is generally placed upright,and can be directly connected to the customer’s production line pipeline.
“I”type K100 capsule filter: It can be placed vertically or horizontally.Equivalent to stainless steel pipe filter.
“L”type K100 capsule: standplaced upright.
“A”type K100 capsule filter: Can be done with stainless steel product stand for placement on platform.Equivalent to stainless steel liquid filter housing.
Digital inks, paintings
•Small injection and tissue cultures in pharmaceutical industry
•Corrosive liquids/solvents filtration in chemical industry
•Photoresist, acids, etc in electronic industry
•Gas/Air sterile filtration
•Laboratory solutions
Use conditions of capsule filter
| Item | Result | |
| Max pressure | 25℃ | 5.0bar |
| Max temperature | 80℃ | 2.0bar |
| Sterilization in sterilization cabinet | 120℃/20 Minutes | 10 times |
| On line steam sterilization | Not available | |
| Gamma ray sterilization | Available | |
| Materials Of Construction | Filter Media: | PP/PES/PVDF/PTFE/Nylon Membranes for Options | ||||
| Support Layers: | Polypropylene | |||||
| Inner core: | Polypropylene/SUS | |||||
| Outer Cage, End caps: | Polypropylene | |||||
| Cartridge Dimensions | Outer Diameter | 100mm(3.93”) | ||||
| Length | 10” | |||||
| Connectors: | Tri clamp 38mm(50.5mm chuck),1/2’’ hose barb,3/4inch hose barb,1’’hose barb. | |||||
| Operating conditions | Normal Operating Temperature: | Up to 60℃ (140℉) | ||||
| Max.Operating Temperature.: | 80℃ (176℉) at △P≤1.0 bar (14psi) | |||||
| Max. Differential Pressure | ||||||
| Normal Flow direction: | 4.2 bar (60 psi) at 25℃ (77℉) | |||||
| Reverse flow direction: | 2.1 bar (30psi) at 25℃ (77℉). | |||||
| Sterilization: | Autoclave sterilization 30 minutes, Gamma-irradiation |
|||||
| Capsule filter | Membrane | Micro | Length | inlet&outlet | ||
| LK | T | S | 10 | 1 | 4H | |
| K100 capsule filter | T=Ttype | S=PES | 010 0.10um | 1=10″ | 4H=1″FLARE | |
| I=Itype | N=Nylon | 020 0.20um | 2=20″ | 6H=3/4″FLARE | ||
| L=Ltype | V=PVDF | 045 0.45um | 3=30″ | 8H=2″FLARE | ||
| A=Atype | F=PTFE | 065 0.65um | 4=40″ | TT=1.5″TC | ||
| P=PP | 100 1.00um | |||||
| G=GF | 300 3.00um | |||||
| 500 5.00um | ||||||
| 1000 10.0um | ||||||
| 2000 20.0um | ||||||
| 4000 40.0um | ||||||
| e.g.:“LKTS0101TT”means the inlet and outlet of T type capsule filter is 1.5“TC and the filter cartridge is 10″PES0.1um. | ||||||
Product detail pictures:
Related Product Guide:
We've been commitment to offer the competitive rate ,outstanding merchandise good quality, too as fast delivery for Fast delivery Lab Capsule Filter - Big Volume Disposable Capsule Filter – Tianshan , The product will supply to all over the world, such as: Mexico, Angola, Vietnam, With a wide range, good quality, reasonable prices and stylish designs, our products are extensively used in public placesand other industries. Our products are widely recognized and trusted by users and can meet continuously developing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!